QCM Research

QCM Research
Temecula, California 92590 USA

 
Home CQCM Mark 10 Mark 20 Mark 21 Mark 24 Model 2000 VODKA

Directory


QCM Home

CQCMs

MK16, 17, 18, 19

TQCMs

MK10
MK20
MK24

Passive QCM

MK21

Controllers

Model 2000

Model 3000

FEU
(Flight Unit)

Test System

VODKA

Information

Documents

Links

Software

FAQ

International Reps

Model 2000TM Controller
Any QCM, Any Combination, Up to 12 Channels


The Model 2000 Control/Data Acquisition Unit (M2000) is the very best lab-quality controller on the market for control and data gathering functions associated with quartz crystal microbalances.

The Model 2000  was designed to meet the growing need for a cost-effective, yet efficient means of interfacing any combination of up to twelve of our various QCM mass sensors (MK9, MK10, MK16, MK17, MK18, MK19, MK21, MK23 and MK24) to a general purpose host computer.

With a minimal front panel, the M2000 communicates with the host computer over an industry standard RS232 serial link.  It accommodates both Si-diode and PRT temperature sensors, and will drive wire wound heaters, PRT heaters, and single, dual and 3-stage thermoelectric elements.  Additionally, it is able to power an external heater, such as is used for an effusion cell.

While autonomously controlling the temperature, both temperature and frequency data for each channel are sent to the host over the serial link.  The base unit can handle four channels, expandable to twelve channels in steps of four.  The data is sent to the host at a rate of one reading per second per channel.

The temperature data sent to the host is given in degrees Kelvin, with the least significant digit representing 1/100 of a Kelvin (0.01 K).  The electronics add no more than 1/4 of a Kelvin (<0.25 K) error to the accuracy of the sensor for absolute accuracy.  For relative accuracy, which eliminates thermal drift, the added error is less than 1/10 of a Kelvin (<0.1 K).

Frequency data sent to the host is given in Hertz.  The relative accuracy is better than one part per million (>1 ppm).  For all frequencies (1 KHz to 600 KHz), seven digits with a floating decimal point is sent.  Thus, for a frequency of 100 KHz, the least significant digit represents 1/10 Hz (0.1 Hz).

The software included is simple to install and use, with an integral programming language which allows for simple command sequences, if desired.  A host computer with software installed can be supplied, if requested, or an in-house computer may be used.


M2000 System Monitor




Specifications
Sensors Si-Diode, PRT Scale Hertz
Scale Kelvin Accuracy
(Relative)
>1 ppm
Resolution 0.01 K Range 1 to 600 KHz
Accuracy (Absolute)
Accuracy (Relative)
>0.25 K
>0.1 K
Resolution 7 Digits Floating point, LSD for 100KHz is 0.1Hz
Weight 16.5 lbs. (7.5 kg) Operating Temp. 10 to 40șC
Power Requirement 300 Watts,
(with 12 TQCMs)
90-264 VAC,
47-440 Hz
Dimensions 19" x 8.75" x 13"
48.25cm x 22.22cm x 56.45cm



QCM Research
42232 Rio Nedo, Suite A
Temecula, California 92590
Phone: 951.694.9539
FAX: 951.694.9538


E-Mail: information@qcmresearch.com